C9900-C559processor 4th Generation Intel® Core™ i3 4330TE, 2.4 GHz, 2 cores (TC3: 60), 
instead of Intel® Pentium® G3320TE 2.3 GHz (TC3: 50)
C9900-C568processor 4th Generation Intel® Core™ i3 4350T, 3.1 GHz, 2 cores (TC3: 60), 
instead of Intel® Pentium® G3320TE 2.3 GHz (TC3: 50)
C9900-C560processor 4th Generation Intel® Core™ i5 4570TE, 2.7 GHz, 2 cores (TC3: 70), 
instead of Intel® Pentium® G3320TE 2.3 GHz (TC3: 50)
C9900-C569processor 4th Generation Intel® Core™ i5 4590T, 2.0 GHz, 4 cores (TC3: 70), 
instead of Intel® Pentium® G3320TE 2.3 GHz (TC3: 50)
C9900-C561processor 4th Generation Intel® Core™ i7 4770TE, 2.3 GHz, 4 cores (TC3: 80), 
instead of Intel® Pentium® G3320TE 2.3 GHz (TC3: 50)
C9900-R257memory extension to 4 GB DDR3L RAM, instead of 2 GB, requires a 64 bit operating system or only 3 GB are addressable
C9900-R258memory extension to 8 GB DDR3L RAM, instead of 2 GB, requires a 64 bit operating system
C9900-R259memory extension to 16 GB DDR3L RAM, instead of 2 GB, requires a 64 bit operating system
C9900-R260memory extension to 32 GB DDR3L RAM, instead of 2 GB, requires a 64 bit operating system
C9900-M711telescope rails to be mounted at the sides of the C51xx, for complete pull-out from the 19-inch rack
C9900-E1952 USB ports of the motherboard led out in one slot bracket
C9900-E1662 serial interfaces RS232 of the motherboard led out with 2 D-sub 9-pin connectors in one slot bracket
C9900-E2031 serial port RS232 from the motherboard led out with one D-sub, 9-pin connector in one slot bracket
C9900-E209Module to optically link one serial RS232 port of the motherboard, with overload protection, 
D-sub, 9-pin, to be mounted inside of slot bracket C9900-M568, C9900-M569 or inside a C66xx 
at the connector bracket C9900-M571. A bracket is required.
C9900-E210Module to convert one serial RS232 port of the motherboard into RS485, configured as an end point 
without echo, D-sub, 9-pin, optically linked, overload protection, to be mounted inside the slot brackets C9900-M568, C9900-M569 or inside a C66xx at the connector bracket C9900-M571. 
A slot bracket is required.
C9900-E211Module to convert one serial RS232 port of the motherboard into RS422, 
configured as a full duplex end point, D-sub, 9-pin, optically linked, overload protection, 
to be mounted inside the slot brackets C9900-M568, C9900-M569 or inside a C66xx at 
the connector bracket C9900-M571. A bracket is required.
C9900-M568Slot bracket for one serial port C9900-E209, C9900-E210 or C9900-E211. Can be ordered only together with one module.
C9900-M569Slot bracket for two serial ports C9900-E209, C9900-E210 or C9900-E211. Can be ordered only together with two modules.
C9900-D192slot for 1 CFast card, SATA connector, for installation into a plug-in card slot
C9900-H58530 GB CFast card, 3D flash, extended temperature range, instead of 3½-inch hard disk
C9900-H58960 GB CFast card, 3D flash, extended temperature range, instead of 3½-inch hard disk
C9900-H5564 GB CFast card, SLC flash, extended temperature range, instead of 3½-inch hard disk, less price
C9900-H5578 GB CFast card, SLC flash, extended temperature range, instead of 3½-inch hard disk, less price
C9900-H55816 GB CFast card, SLC flash, extended temperature range, instead of 3½-inch hard disk
C9900-H56632 GB CFast card, SLC flash, extended temperature range, instead of 3½-inch hard disk
C9900-H57064 GB CFast card, SLC flash, extended temperature range, instead of 3½-inch hard disk
C9900-H201hard disk drive, 3½-inch, 2 TB, instead of hard disk 1 TB
C9900-H202hard disk drive, 3½-inch, 4 TB, instead of hard disk 1 TB, requires a 64 bit operating system and UEFI instead of BIOS
C9900-B528BIOS for booting from storage media bigger than 2 TB, UEFI activated
C9900-H152additional hard disk drive, 3½-inch, 1 TB
C9900-H203additional hard disk drive, 3½-inch, 2 TB
C9900-H204additional hard disk drive, 3½-inch, 4 TB
C9900-H754solid-state disk SSD, 3D flash, 2½-inch, 120 GB, with mounting adapter, instead of 3½-inch hard disk
C9900-H755solid-state disk SSD, 3D flash, 2½-inch, 240 GB, with mounting adapter, instead of 3½-inch hard disk
C9900-H756solid-state disk SSD, 3D flash, 2½-inch, 480 GB, with mounting adapter, instead of 3½-inch hard disk
C9900-H704solid-state disk SSD, SLC flash, 2½-inch, 32 GB, with mounting adapter, instead of 3½-inch hard disk
C9900-H709solid-state disk SSD, SLC flash, 2½-inch, 64 GB, with mounting adapter, instead of 3½-inch hard disk
C9900-H740solid-state disk SSD, SLC flash, 2½-inch, 128 GB, with mounting adapter, instead of 3½-inch hard disk
C9900-M617removable frame for a 3½-inch hard disk
C9900-M628removable frame for a 2½-inch SSD
C9900-H741solid-state disk SSD, 3D flash, 2½-inch, 120 GB
C9900-H749solid-state disk SSD, 3D flash, 2½-inch, 240 GB
C9900-H745solid-state disk SSD, 3D flash, 2½-inch, 480 GB
C9900-H743solid-state disk SSD, 3D flash, 2½-inch, 120 GB, instead of 3½-inch hard disk
C9900-H751solid-state disk SSD, 3D flash, 2½-inch, 240 GB, instead of 3½-inch hard disk
C9900-H747solid-state disk SSD, 3D flash, 2½-inch, 480 GB, instead of 3½-inch hard disk
C9900-H700solid-state disk SSD, SLC flash, 2½-inch, 32 GB
C9900-H705solid-state disk SSD, SLC flash, 2½-inch, 64 GB
C9900-H735solid-state disk SSD, SLC flash, 2½-inch, 128 GB
C9900-H702solid-state disk SSD, SLC flash, 2½-inch, 32 GB, instead of 3½-inch hard disk
C9900-H707solid-state disk SSD, SLC flash, 2½-inch, 64 GB, instead of 3½-inch hard disk
C9900-H737solid-state disk SSD, SLC flash, 2½-inch, 128 GB, instead of 3½-inch hard disk
C9900-D120CD-DVD-ROM drive
C9900-D245multi DVD drive, reads CD-ROM and DVD-ROM, reads and writes CD-R-RW, 
DVD-R+R-RW+RW 4.7 GB and DVD-R+R DL 8.5 GB
C9900-P20824 V DC power supply, instead of 100–240 V AC full range power supply, occupies one serial port
C9900-P20924 V DC power supply with integrated UPS, instead of 100–240 V AC full range power supply,
occupies one serial port
C9900-U330battery pack for PCs with 24 V power supply and integrated UPS C9900-P209 or C9900-U209, external, 
for DIN rail mounting, 3.4 Ah, operating temperature 0…50 °C
C9900-P313redundant ATX power supply for C5102, 100-240 V AC, 450 W, instead of standard power supply
C9900-U120uninterruptible power supply UPS, external, 230 V
C9900-U122uninterruptible power supply UPS, external, 115 V
C9900-M623wall mounting frame for uninterruptible power supply C9900-U120, C9900-U122 and C9900-U124
C9900-xxxxFlash cards, PCI and PCIe cards as listed in the attachment.
Examples: Compact Flash, CFast, fieldbus interface, network adapter, serial interface card, modem

C5102-0030- 19-inch slide-in Industrial PC

Mail: Sale08@tmpvietnam.com
Mobile Phone: 0917.543.068 - 01654.00.88.66 

C5102-0030- 19-inch slide-in Industrial PC




















BK1120 EtherCAT Bus Coupler - Beckhoff VietNam

Mail: Sale08@tmpvietnam.com
Mobile Phone: 0917.543.068 - 01654.00.88.66 

BK1120 EtherCAT Bus Coupler - Beckhoff VietNam
























BK1120 | EtherCAT Bus Coupler

EtherCATThe BK1120 Bus Coupler connects EtherCAT, the real-time Ethernet system, with the modular, extendable electronic terminal blocks. A unit consists of a Bus Coupler, any number (between 1 and 64) of terminals (255 with K-bus extension) and one end terminal.
The Bus Coupler recognises the connected Bus Terminals and automatically allocates them into the EtherCAT process image. The Bus Coupler is connected to the network via the upper Ethernet interface. The lower RJ45 socket may be used to connect further EtherCAT devices in the same strand.
In the EtherCAT network, the BK1120 Bus Coupler can be installed anywhere in the Ethernet signal transfer section (100BASE-TX) – except directly at the switch. The Bus Coupler BK9000 (for K-bus components) is suitable for installation at the switch.
EtherCAT (Ethernet Control Automation Technology) is the Ethernet solution for industrial automation, characterised by outstanding performance and particularly simple handling. EtherCAT enables the Ethernet star topology to be replaced with a simple line structure. Optionally, EtherCAT may also be wired in the “classic” way using switches, in order to integrate further Ethernet devices. The master requires no special plug-in card and can be implemented on any existing Ethernet controller using a very simple interface. EtherCAT is therefore also well suited to small and medium control applications, where it will also open up new areas of application for distributed I-Os.
For EtherCAT a separate I-O system in protection class IP 20 is available in the form of EtherCAT Terminals. In contrast to Bus Terminals, where the fieldbus signal is implemented within the Bus Coupler on the internal, fieldbus-independent terminal bus, the EtherCAT protocol remains fully intact down to the individual terminal. The ELxxxx EtherCAT Terminals are connected via associated EKxxxx-type EtherCAT Couplers (see EtherCAT section).

System dataEtherCAT | BK1120
Number of I-O stations65,535
Number of I-O pointsdepending on controller
Data transfer mediumEthernet-EtherCAT Cat.5 cable
Max. cable length100 m (100BASE-TX)
Data transfer rates100 Mbaud
Data transfer time0.01 ms in the case of 10 modules for 32 bit inputs and outputs each (without K-bus run-time)
Technical dataBK1120
Number of Bus Terminals64 (255 with K-bus extension)
Max. number of bytes fieldbus1024 byte input and 1024 byte output
Configuration possibilityvia KS2000 or EtherCAT (ADS)
Bus interface2 x RJ45
Power supply24 V DC (-15 %+20 %)
Input current70 mA + (total K-bus current)4, 500 mA max.
Starting currentapprox. 2.5 x continuous current
Recommended fuse≤ 10 A
Current supply K-bus1750 mA
Power contacts24 V DC max.10 A max.
Electrical isolation500 V (power contact-supply voltage-Ethernet)
Distance between stations100 m (100BASE-TX)
Weightapprox. 150 g
Operating-storage temperature-25…+60 °C-40…+85 °C
Relative humidity95 %, no condensation
Vibration-shock resistanceconforms to EN 60068-2-6EN 60068-2-27
EMC immunity-emissionconforms to EN 61000-6-2EN 61000-6-4
Protect. class-installation pos.IP 20-variable
ApprovalsCE, UL, Ex
Accessories 
KS2000configuration software for extended parameterisation
Cordsetscordsets and connectors
FC9001-0010 | FC9011Ethernet PCI fieldbus cards
Related products 
BK1150EtherCAT “Compact” Bus Coupler for up to 64 Bus Terminals (255 with K-bus extension)
BK1250EtherCAT “Compact“ Coupler between EtherCAT Terminals (E-bus) and Bus Terminals (K-bus), adapter terminal
CX8010EtherCAT Embedded PC
System 
EtherCATFor further EtherCAT products please see the system overview

CANopen Bus Coupler BK5120

Mail: Sale08@tmpvietnam.com
Mobile Phone: 0917.543.068 - 01654.00.88.66 

BK5120 | CANopen Bus Coupler

CANopenThe BK5120 “Economy plus” Bus Coupler connects the CAN bus system to the electronic 
terminal blocks, which can be extended in modular fashion. One unit consists of one Bus Coupler, any number 
of up to 64 terminals and one end terminal. With the K-bus extension technology, the BK5120 allows t
he connection of up to 255 spatially distributed Bus Terminals to one Bus Coupler.
The Bus Coupler works on the CAN protocol basis as defined in ISO 11898. In addition to network services, 
CANopen also determines the data allocation for automation systems applications and has established itself as
 an open CAN application layer. The Bus Coupler supports all types of CANopen communications and can also 
be used without difficulty in manufacturer-specific CAN environments due to the simple structure of this protocol 
definition. The firmware can be updated via the configuration interface.
Parameterising can also be carried out using any CANopen configuration tools. For this, EDS data files are available,
 which describe all the setting options for the CANopen coupler. For most applications, however, no configuration is 
necessary, as CANopen provides practical default values for all parameters.

System dataCANopen | BK5120
Number of I-O stations64 (BK5120: 255 with K-bus extension)
Number of I-O pointsdepends on the structure
Data transfer mediumscreened, twisted copper cable, 2 x signal, 1 x ground (recommended)
Max. cable length
5,000 m2,500 m1,000 m500 m250 m100 m40 m
Data transfer rates
10 kbaud20 kbaud50 kbaud100-125 kbaud250 kbaud500 kbaud1,000 kbaud
PDO modessynchron, cyclic, event driven, polling
Technical dataBK5120
Number of Bus Terminals64 (255 with K-bus extension)
Max. number of bytes fieldbus16 Tx-Rx PDOs
Digital peripheral signals960 inputs-outputs
Analog peripheral signals60 inputs-outputs
Configuration possibilityvia KS2000 or the controller
Number of PDOs (CANopen)16 Tx16 Rx
Additional CANopen featureslife, node guarding, emergency object, variable mapping, store-restore
Data transfer ratesup to 1 Mbaud
Bus interface1 x open style connector, 5-pin, included
Power supply24 V DC (-15 %+20 %)
Input current70 mA + (total K-bus current)4, 500 mA max.
Starting currentapprox. 2.5 x continuous current
Recommended fuse≤ 10 A
Current supply K-bus1750 mA
Power contacts24 V DC max.10 A max.
Electrical isolation500 V (power contact-supply voltage Bus Coupler)
Weightapprox. 150 g
Operating-storage temperature-25…+60 °C-40…+85 °C
Relative humidity95 %, no condensation
Vibration-shock resistanceconforms to EN 60068-2-6EN 60068-2-27
EMC immunity-emissionconforms to EN 61000-6-2EN 61000-6-4
Protect. class-installation pos.IP 20variable
ApprovalsCE, UL, Ex, GL
Accessories 
KS2000configuration software for extended parameterisation
Cordsetscordsets and connectors
FC5101 | FC5102CANopen PCI fieldbus cards
Related products 
BK5110CANopen Coupler for up to 64 digital Bus Terminals
BK5150CANopen “Compact” Bus Coupler for up to 64 Bus Terminals (255 with K-bus extension)
BK5151CANopen “Compact” Bus Coupler for up to 64 Bus Terminals (255 with K-bus extension)
LC5100CANopen “Low Cost“ Bus Coupler version for up to 64 digital Bus Terminals (255 with K-bus extension)
BC5150CANopen “Compact” Bus Terminal Controller for up to 64 Bus Terminals (255 with K-bus extension)
BX5100CANopen Bus Terminal Controller for up to 64 Bus Terminals (255 with K-bus extension)
CX8051CANopen Embedded PC, slave
System 
CANopenFor further CANopen products please see the system overview