B MAXX 4400 POWER MODULES WITH FIVE COOLING CONCEPTS AND SEVEN FRAME SIZES

Name: Sĩ Nguyên (Mr)
Mail: Sale08@tmpvietnam.com
Mobile Phone: 0917.543.068 - 01654.00.88.66 






Technical data b maXX 4000ES air cooling



Frame size
IN [A]
IMAX[A]
typ. motor power [kW]
Overload factor
Dimensions WxHxD [mm]

BM 4412
1
2.5
5
1.1
2
106 x 310 x 263
BM 4413
1
4.5
9
2
2
106 x 310 x 263
BM 4422
2
7.5
15
3.4
2
106 x 428 x 340
BM 4423
2
11
22
5
2
106 x 428 x 340
BM 4424
2
15
30
6.8
2
106 x 428 x 340
BM 4425
2
15
40 1)
6.8
2.6
106 x 428 x 340
BM 4426
2
22.5
45 1)
10
2
106 x 428 x 340
BM 4432
3
22.5
45
10
2
155 x 510 x 340
BM 4433
3
30
60
13
2
155 x 510 x 340
BM 4434
3
45
90
20
2
155 x 510 x 340
BM 4435
3
60
90
28
1.5
155 x 510 x 340
BM 4443
4
80
120
36
1.5
190 x 624 x 374
BM 4444
4
100
130
45
1.3
190 x 624 x 374
BM 4445
4
130
170
58
1.3
190 x 624 x 374
BM 4453
5
150
195
75
1.3
307 x 656 x 374
BM 4454
5
210
260
110
1.3
307 x 656 x 374
BM 4462
6
250
325
132
1.3
437 x 815 x 378
BM 4463
6
300
390
160
1.3
437 x 815 x 378
BM 4472
7
450
585
225
1.3
520 x 600 x 340 2)
BM 4473
7
600
780
315
1.3
520 x 600 x 340 2)



Supply voltage: 207–528 V ± 0% AC
Supply frequency: 50/60 Hz
Supply rated voltage: 400 V
DC link voltage: 540 V rated voltage
Chopping frequency: 2/4/8 kHz
Output voltage: 0–95% of supply voltage
Electronics supply: external 24 V DC (diagnostic capability)
Fan connection: frame sizes 1–3: 24 V DC; frame sizes 4–7: 230 V AC ± 10%
Certification: CE, CSA, UL
Height and depth without mounting brackets.
Depth including required bending radius of connecting cables .
1) for 1 second
2) dimensions of water-cooled version
*) in preparation




Comments